*Any split, multi-split or ducted system installed after the 1st of July in a domestic/residential application will come with a 7-year warranty.
| Cooling Capacity | kW | 12.5 |
| Cooling Capacity Range | kW | 3.60-14.00 |
| Heating Capacity | kW | 14 |
| Heating Capacity Range | kW | 4.20-15.00 |
| EER | W/W | 3.3967 |
| COP | W/W | 3.8043 |
| AEER | — | 3.3809 |
| ACOP | — | 3.7866 |
| Cooling Star Rating (Hot/Avg/Cold) | - | 4 / 3.5 / 4 |
| Cooling Energy Consumption (Hot/Avg/Cold) | kWh | 2932 / 959 / 612 |
| Heating Star Rating (Hot/Avg/Cold) | - | 3.5 / 2.5 / 2 |
| Heating Energy Consumption (Hot/Avg/Cold) | kWh | 236 / 1792 / 5215 |
| Cooling Power Input | kW | 3.68 |
| Cooling Power Input Range | kW | 0.70-5.20 |
| Cooling Rated Power Input | kW | 5.2 |
| Cooling Current Input | A | 16.9 |
| Cooling Current Input Range | A | 3.20-25.00 |
| Cooling Rated Current | A | 25 |
| Heating Power Input | kW | 3.68 |
| Heating Power Input Range | kW | 0.80-5.20 |
| Heating Rated Power Input | kW | 5.2 |
| Heating Current Input | A | 16.9 |
| Heating Current Input Range | A | 3.70-25.00 |
| Heating Rated Current | A | 25 |
| Standby power consumption | W | 5.1 |
| Indoor Fan Motor Speed | rpm | 800/760/720/680 |
| Indoor Air Flow Volume | m3/h | 2800/2500/2200/1800 |
| Indoor Air Flow Volume | l/s | 778/694/611/500 |
| Indoor Air Flow Volume | CFM | 1647/1470/1294/1059 |
| External Static Pressure | Pa | 50 |
| External Static Pressure Range | Pa | 0-200 |
| Indoor Sound Pressure Level (H) | dB(A) | 42 |
| Indoor Sound Pressure Level (M) | dB(A) | 40 |
| Indoor Sound Pressure Level (L) | dB(A) | 39 |
| Indoor Sound Power Level (Test) | dB(A) | 65 |
| Outdoor Air Flow Volume | m3/h | 5200 |
| Outdoor Air Flow Volume | CFM | 3060.2 |
| Outdoor Sound Pressure Level (H) | dB(A) | 59 |
| Outdoor Sound Power Level (Test) | dB(A) | 73 |
| Dehumidifying Volume | L/h | 3.5 |
| Rated Voltage | V | 220-240 |
| Rated Frequency | Hz | 50/60 |
| Phases | - | 1 |
| Min/Max. Voltage | V | 198/264 |
| Cross-sectional Area of Power Cable Conductor | mm2 | 4 |
| Cross-sectional Area of Power Cable Conductor | sq in | 0.0062 |
| Recommended Power Cable(Core) | N | 3 |
| Indoor Fuse Current | A | 10 |
| Outdoor Fuse Current | A | — |
| Circuit Breaker | A | 32 |
| Application Area | m2 | 55-85 |
| Compressor Type | - | Inverter Rotary |
| Compressor Quantity | - | 1 |
| Compressor Capacity | W | 9529 |
| Compressor Power Input | W | 3200 |
| Compressor Rated Load Amp (RLA) | A | 4.9 |
| Indoor Fan Type | - | Centrifugal |
| Indoor Fan Quantity | - | 2 |
| Outdoor Fan Type | - | Axial-flow |
| Outdoor Fan Quantity | - | 1 |
| Fan Motor Drive Type | - | Direct |
| Outdoor Fan Motor Speed | rpm | 820 |
| Condenser Max. Allowable Pressure | MPa | 10 |
| Permissible Excessive Operating Pressure for the Discharge Side | MPa | 4.6 |
| Permissible Excessive Operating Pressure for the Suction Side | MPa | 2.5 |
| Maximum Allowable Pressure | MPa | 4.6 |
| High Presser Overload Protector | MPa | Protection:4.6 Recovery:3.8 |
| Low Presser Overload Protector | MPa | Protection:0.05 Recovery:0.15 |
| Cooling Operation Ambient Temperature Range | ℃ | –15~52 |
| Cooling Operation Ambient Temperature Range | ℉ | 5~125.6 |
| Heating Operation Ambient Temperature Range | ℃ | –15~24 |
| Heating Operation Ambient Temperature Range | ℉ | 5~75.2 |
| Defrosting Method | — | Auto defrost |
| Isolation | - | I |
| Outdoor Moisture Protection | — | IPX4 |
| Overload Protector | - | High Presser Protector Low presser protector |
| Climate Type | - | T1 |
| Refrigerant | - | R32 |
| Refrigerant Charge | kg | 2.4 |
| Throttling Method | - | Electronic expansion valve |
| Connection Pipe Length | m | 5 |
| Test Connection Pipe Length | m | 5 |
| Not Additional Gas Connection Pipe Length | m | 15 |
| Connection Pipe Gas Additional Charge | g/m | 25 |
| Connection Pipe Outer Diameter of Liquid Pipe | mm | φ9.52 |
| Connection Pipe Outer Diameter of Liquid Pipe | inch | 3/8″ |
| Connection Pipe Outer Diameter of Gas Pipe | mm | φ16 |
| Connection Pipe Outer Diameter of Gas Pipe | inch | 5/8″ |
| Connection Pipe Max. Height Distance | m | 30 |
| Connection Pipe Max. Length Distance | m | 75 |
| Suppliy Air Outlet (W x H) | mm | 850 x 190 |
| Return Air Inlet (W x H) | mm | 1170 x 326 |
| Indoor Dimension of Outline(W x D x H) | mm | 1350 x 720 x 360 |
| Indoor Dimension of Carton Box(L x W x H) | mm | 1565 x 861 x 433 |
| Indoor Dimension of Package(L x W x H) | mm | 1568 x 864 x 448 |
| Indoor Net Weight (Net/Gross) | kg | 57 / 67 |
| Outdoor Dimension of Outline(W x D x H) | mm | 940 x 370 x 820 |
| Outdoor Dimension of Carton Box(L x W x H) | mm | 1090 x 494 x 850 |
| Outdoor Dimension of Package(L x W x H) | mm | 1098 x 503 x 970 |
| Outdoor Net Weight (Net/Gross) | kg | 67 / 79 |
| Indoor Unit Loading Quantity ( 20’ Container ) | unit | 35 |
| Indoor Unit Loading Quantity ( 40’ Container ) | unit | 75 |
| Indoor Unit Loading Quantity ( 40’ High Cube Container ) | unit | 75 |
| Indoor Unit Stacked Layers | - | 5 |
| Outdoor Unit Loading Quantity ( 20’ Container ) | unit | 44 |
| Outdoor Unit Loading Quantity ( 40’ Container ) | unit | 92 |
| Outdoor Unit Loading Quantity ( 40’ High Cube Container ) | unit | 92 |
| Outdoor Unit Stacked Layers | - | 2 |
| Loading Quantity ( 20’ Container ) | unit | 21 |
| Loading Quantity ( 40’ Container ) | unit | 47 |
| Loading Quantity ( 40’ High Cube Container ) | unit | 47 |
| Cooling Capacity | kW | 12.5 |
| Cooling Capacity Range | kW | 3.60-14.00 |
| Heating Capacity | kW | 14 |
| Heating Capacity Range | kW | 4.20-15.00 |
| EER | W/W | 3.3967 |
| COP | W/W | 3.8043 |
| AEER | — | 3.3809 |
| ACOP | — | 3.7866 |
| Cooling Star Rating (Hot/Avg/Cold) | - | 4 / 3.5 / 4 |
| Cooling Energy Consumption (Hot/Avg/Cold) | kWh | 2932 / 959 / 612 |
| Heating Star Rating (Hot/Avg/Cold) | - | 3.5 / 2.5 / 2 |
| Heating Energy Consumption (Hot/Avg/Cold) | kWh | 236 / 1792 / 5215 |
| Cooling Power Input | kW | 3.68 |
| Cooling Power Input Range | kW | 0.70-5.20 |
| Cooling Rated Power Input | kW | 5.2 |
| Cooling Current Input | A | 16.9 |
| Cooling Current Input Range | A | 3.20-25.00 |
| Cooling Rated Current | A | 25 |
| Heating Power Input | kW | 3.68 |
| Heating Power Input Range | kW | 0.80-5.20 |
| Heating Rated Power Input | kW | 5.2 |
| Heating Current Input | A | 16.9 |
| Heating Current Input Range | A | 3.70-25.00 |
| Heating Rated Current | A | 25 |
| Standby power consumption | W | 5.1 |
| Indoor Fan Motor Speed | rpm | 800/760/720/680 |
| Indoor Air Flow Volume | m3/h | 2800/2500/2200/1800 |
| Indoor Air Flow Volume | l/s | 778/694/611/500 |
| Indoor Air Flow Volume | CFM | 1647/1470/1294/1059 |
| External Static Pressure | Pa | 50 |
| External Static Pressure Range | Pa | 0-200 |
| Indoor Sound Pressure Level (H) | dB(A) | 42 |
| Indoor Sound Pressure Level (M) | dB(A) | 40 |
| Indoor Sound Pressure Level (L) | dB(A) | 39 |
| Indoor Sound Power Level (Test) | dB(A) | 65 |
| Outdoor Air Flow Volume | m3/h | 5200 |
| Outdoor Air Flow Volume | CFM | 3060.2 |
| Outdoor Sound Pressure Level (H) | dB(A) | 59 |
| Outdoor Sound Power Level (Test) | dB(A) | 73 |
| Dehumidifying Volume | L/h | 3.5 |
| Rated Voltage | V | 220-240 |
| Rated Frequency | Hz | 50/60 |
| Phases | - | 1 |
| Min/Max. Voltage | V | 198/264 |
| Cross-sectional Area of Power Cable Conductor | mm2 | 4 |
| Cross-sectional Area of Power Cable Conductor | sq in | 0.0062 |
| Recommended Power Cable(Core) | N | 3 |
| Indoor Fuse Current | A | 10 |
| Outdoor Fuse Current | A | — |
| Circuit Breaker | A | 32 |
| Application Area | m2 | 55-85 |
| Compressor Type | - | Inverter Rotary |
| Compressor Quantity | - | 1 |
| Compressor Capacity | W | 9529 |
| Compressor Power Input | W | 3200 |
| Compressor Rated Load Amp (RLA) | A | 4.9 |
| Indoor Fan Type | - | Centrifugal |
| Indoor Fan Quantity | - | 2 |
| Outdoor Fan Type | - | Axial-flow |
| Outdoor Fan Quantity | - | 1 |
| Fan Motor Drive Type | - | Direct |
| Outdoor Fan Motor Speed | rpm | 820 |
| Condenser Max. Allowable Pressure | MPa | 10 |
| Permissible Excessive Operating Pressure for the Discharge Side | MPa | 4.6 |
| Permissible Excessive Operating Pressure for the Suction Side | MPa | 2.5 |
| Maximum Allowable Pressure | MPa | 4.6 |
| High Presser Overload Protector | MPa | Protection:4.6 Recovery:3.8 |
| Low Presser Overload Protector | MPa | Protection:0.05 Recovery:0.15 |
| Cooling Operation Ambient Temperature Range | ℃ | –15~52 |
| Cooling Operation Ambient Temperature Range | ℉ | 5~125.6 |
| Heating Operation Ambient Temperature Range | ℃ | –15~24 |
| Heating Operation Ambient Temperature Range | ℉ | 5~75.2 |
| Defrosting Method | — | Auto defrost |
| Isolation | - | I |
| Outdoor Moisture Protection | — | IPX4 |
| Overload Protector | - | High Presser Protector Low presser protector |
| Climate Type | - | T1 |
| Refrigerant | - | R32 |
| Refrigerant Charge | kg | 2.4 |
| Throttling Method | - | Electronic expansion valve |
| Connection Pipe Length | m | 5 |
| Test Connection Pipe Length | m | 5 |
| Not Additional Gas Connection Pipe Length | m | 15 |
| Connection Pipe Gas Additional Charge | g/m | 25 |
| Connection Pipe Outer Diameter of Liquid Pipe | mm | φ9.52 |
| Connection Pipe Outer Diameter of Liquid Pipe | inch | 3/8″ |
| Connection Pipe Outer Diameter of Gas Pipe | mm | φ16 |
| Connection Pipe Outer Diameter of Gas Pipe | inch | 5/8″ |
| Connection Pipe Max. Height Distance | m | 30 |
| Connection Pipe Max. Length Distance | m | 75 |
| Suppliy Air Outlet (W x H) | mm | 850 x 190 |
| Return Air Inlet (W x H) | mm | 1170 x 326 |
| Indoor Dimension of Outline(W x D x H) | mm | 1350 x 720 x 360 |
| Indoor Dimension of Carton Box(L x W x H) | mm | 1565 x 861 x 433 |
| Indoor Dimension of Package(L x W x H) | mm | 1568 x 864 x 448 |
| Indoor Net Weight (Net/Gross) | kg | 57 / 67 |
| Outdoor Dimension of Outline(W x D x H) | mm | 940 x 370 x 820 |
| Outdoor Dimension of Carton Box(L x W x H) | mm | 1090 x 494 x 850 |
| Outdoor Dimension of Package(L x W x H) | mm | 1098 x 503 x 970 |
| Outdoor Net Weight (Net/Gross) | kg | 67 / 79 |
| Indoor Unit Loading Quantity ( 20’ Container ) | unit | 35 |
| Indoor Unit Loading Quantity ( 40’ Container ) | unit | 75 |
| Indoor Unit Loading Quantity ( 40’ High Cube Container ) | unit | 75 |
| Indoor Unit Stacked Layers | - | 5 |
| Outdoor Unit Loading Quantity ( 20’ Container ) | unit | 44 |
| Outdoor Unit Loading Quantity ( 40’ Container ) | unit | 92 |
| Outdoor Unit Loading Quantity ( 40’ High Cube Container ) | unit | 92 |
| Outdoor Unit Stacked Layers | - | 2 |
| Loading Quantity ( 20’ Container ) | unit | 21 |
| Loading Quantity ( 40’ Container ) | unit | 47 |
| Loading Quantity ( 40’ High Cube Container ) | unit | 47 |

Conveniently fits in more places.

Comfort without all the noise.
© Copyright 2024 TECO Pty Ltd