| Cooling Capacity | kW | 16 |
| Cooling Capacity Range | kW | 4.80-18.00 |
| Heating Capacity | kW | 18 |
| Heating Capacity Range | kW | 5.40-20.00 |
| EER | W/W | 3.3333 |
| COP | W/W | 3.8710 |
| AEER | — | 3.3105 |
| ACOP | — | 3.8436 |
| Cooling Star Rating (Hot/Avg/Cold) | - | 3.5 / 3 / 3.5 |
| Cooling Energy Consumption (Hot/Avg/Cold) | kWh | 4138 / 1375 / 876 |
| Heating Star Rating (Hot/Avg/Cold) | - | 3.5 / 2.5 / 2 |
| Heating Energy Consumption (Hot/Avg/Cold) | kWh | 325 / 2320 / 6519 |
| Cooling Power Input | kW | 4.8 |
| Cooling Power Input Range | kW | 0.90-7.00 |
| Cooling Rated Power Input | kW | 7 |
| Cooling Current Input | A | 22 |
| Cooling Current Input Range | A | 4.10-32.00 |
| Cooling Rated Current | A | 32 |
| Heating Power Input | kW | 4.65 |
| Heating Power Input Range | kW | 1.00-7.00 |
| Heating Rated Power Input | kW | 7 |
| Heating Current Input | A | 21.3 |
| Heating Current Input Range | A | 4.60-32.00 |
| Heating Rated Current | A | 32 |
| Standby power consumption | W | 9.8 |
| Indoor Fan Motor Speed | rpm | 960/900/840/780 |
| Indoor Air Flow Volume | m3/h | 3500/3100/2700/2300 |
| Indoor Air Flow Volume | l/s | 972/861/750/639 |
| Indoor Air Flow Volume | CFM | 2059/1824/1588/1353 |
| External Static Pressure | Pa | 50 |
| External Static Pressure Range | Pa | 0-200 |
| Indoor Sound Pressure Level (H) | dB(A) | 50 |
| Indoor Sound Pressure Level (M) | dB(A) | 48 |
| Indoor Sound Pressure Level (L) | dB(A) | 46 |
| Indoor Sound Power Level (Test) | dB(A) | 70 |
| Outdoor Air Flow Volume | m3/h | 7000 |
| Outdoor Air Flow Volume | CFM | 4119.5 |
| Outdoor Sound Pressure Level (H) | dB(A) | 60 |
| Outdoor Sound Power Level (Test) | dB(A) | 73 |
| Dehumidifying Volume | L/h | 4.5 |
| Rated Voltage | V | 220-240 |
| Rated Frequency | Hz | 50/60 |
| Phases | - | 1 |
| Min/Max. Voltage | V | 198/264 |
| Cross-sectional Area of Power Cable Conductor | mm2 | 6 |
| Cross-sectional Area of Power Cable Conductor | sq in | 0.0093 |
| Recommended Power Cable(Core) | N | 3 |
| Indoor Fuse Current | A | 10 |
| Outdoor Fuse Current | A | — |
| Circuit Breaker | A | 40 |
| Application Area | m2 | 95-140 |
| Compressor Type | - | Inverter Rotary |
| Compressor Quantity | - | 1 |
| Compressor Capacity | W | 15320 |
| Compressor Power Input | W | 3830 |
| Compressor Rated Load Amp (RLA) | A | 7.2 |
| Indoor Fan Type | - | Centrifugal |
| Indoor Fan Quantity | - | 2 |
| Outdoor Fan Type | - | Axial-flow |
| Outdoor Fan Quantity | - | 2 |
| Fan Motor Drive Type | - | Direct |
| Outdoor Fan Motor Speed | rpm | 840 |
| Condenser Max. Allowable Pressure | MPa | 10 |
| Permissible Excessive Operating Pressure for the Discharge Side | MPa | 4.6 |
| Permissible Excessive Operating Pressure for the Suction Side | MPa | 2.5 |
| Maximum Allowable Pressure | MPa | 4.6 |
| High Presser Overload Protector | MPa | Protection:4.6 Recovery:3.8 |
| Low Presser Overload Protector | MPa | Protection:0.05 Recovery:0.15 |
| Cooling Operation Ambient Temperature Range | ℃ | -15~52 |
| Cooling Operation Ambient Temperature Range | ℉ | 5~125.6 |
| Heating Operation Ambient Temperature Range | ℃ | -15~24 |
| Heating Operation Ambient Temperature Range | ℉ | 5~75.2 |
| Defrosting Method | — | Auto defrost |
| Isolation | - | I |
| Outdoor Moisture Protection | — | IPX4 |
| Overload Protector | - | High Presser Protector, Discharge High Temperature Protection |
| Climate Type | - | T1 |
| Refrigerant | - | R32 |
| Refrigerant Charge | kg | 3.3 |
| Throttling Method | - | Electronic expansion valve |
| Connection Pipe Length | m | 7.5 |
| Test Connection Pipe Length | m | 7.5 |
| Not Additional Gas Connection Pipe Length | m | 15 |
| Connection Pipe Gas Additional Charge | g/m | 35 |
| Connection Pipe Outer Diameter of Liquid Pipe | mm | φ9.52 |
| Connection Pipe Outer Diameter of Liquid Pipe | inch | 3/8″ |
| Connection Pipe Outer Diameter of Gas Pipe | mm | φ16 |
| Connection Pipe Outer Diameter of Gas Pipe | inch | 5/8″ |
| Connection Pipe Max. Height Distance | m | 30 |
| Connection Pipe Max. Length Distance | m | 75 |
| Suppliy Air Outlet (W x H) | mm | 850 x 190 |
| Return Air Inlet (W x H) | mm | 1170 x 326 |
| Indoor Dimension of Outline(W x D x H) | mm | 1350 x 720 x 360 |
| Indoor Dimension of Carton Box(L x W x H) | mm | 1565 x 861 x 433 |
| Indoor Dimension of Package(L x W x H) | mm | 1568 x 864 x 448 |
| Indoor Net Weight (Net/Gross) | kg | 60 / 70 |
| Outdoor Dimension of Outline(W x D x H) | mm | 900 x 340 x 1260 |
| Outdoor Dimension of Carton Box(L x W x H) | mm | 1025 x 435 x 1285 |
| Outdoor Dimension of Package(L x W x H) | mm | 1033 x 443 x 1405 |
| Outdoor Net Weight (Net/Gross) | kg | 97 / 106 |
| Indoor Unit Loading Quantity ( 20’ Container ) | unit | 35 |
| Indoor Unit Loading Quantity ( 40’ Container ) | unit | 75 |
| Indoor Unit Loading Quantity ( 40’ High Cube Container ) | unit | 75 |
| Indoor Unit Stacked Layers | - | 5 |
| Outdoor Unit Loading Quantity ( 20’ Container ) | unit | 27 |
| Outdoor Unit Loading Quantity ( 40’ Container ) | unit | 57 |
| Outdoor Unit Loading Quantity ( 40’ High Cube Container ) | unit | 57 |
| Outdoor Unit Stacked Layers | - | 1 |
| Loading Quantity ( 20’ Container ) | unit | 20 |
| Loading Quantity ( 40’ Container ) | unit | 42 |
| Loading Quantity ( 40’ High Cube Container ) | unit | 42 |
| Cooling Capacity | kW | 16 |
| Cooling Capacity Range | kW | 4.80-18.00 |
| Heating Capacity | kW | 18 |
| Heating Capacity Range | kW | 5.40-20.00 |
| EER | W/W | 3.3333 |
| COP | W/W | 3.8710 |
| AEER | — | 3.3105 |
| ACOP | — | 3.8436 |
| Cooling Star Rating (Hot/Avg/Cold) | - | 3.5 / 3 / 3.5 |
| Cooling Energy Consumption (Hot/Avg/Cold) | kWh | 4138 / 1375 / 876 |
| Heating Star Rating (Hot/Avg/Cold) | - | 3.5 / 2.5 / 2 |
| Heating Energy Consumption (Hot/Avg/Cold) | kWh | 325 / 2320 / 6519 |
| Cooling Power Input | kW | 4.8 |
| Cooling Power Input Range | kW | 0.90-7.00 |
| Cooling Rated Power Input | kW | 7 |
| Cooling Current Input | A | 22 |
| Cooling Current Input Range | A | 4.10-32.00 |
| Cooling Rated Current | A | 32 |
| Heating Power Input | kW | 4.65 |
| Heating Power Input Range | kW | 1.00-7.00 |
| Heating Rated Power Input | kW | 7 |
| Heating Current Input | A | 21.3 |
| Heating Current Input Range | A | 4.60-32.00 |
| Heating Rated Current | A | 32 |
| Standby power consumption | W | 9.8 |
| Indoor Fan Motor Speed | rpm | 960/900/840/780 |
| Indoor Air Flow Volume | m3/h | 3500/3100/2700/2300 |
| Indoor Air Flow Volume | l/s | 972/861/750/639 |
| Indoor Air Flow Volume | CFM | 2059/1824/1588/1353 |
| External Static Pressure | Pa | 50 |
| External Static Pressure Range | Pa | 0-200 |
| Indoor Sound Pressure Level (H) | dB(A) | 50 |
| Indoor Sound Pressure Level (M) | dB(A) | 48 |
| Indoor Sound Pressure Level (L) | dB(A) | 46 |
| Indoor Sound Power Level (Test) | dB(A) | 70 |
| Outdoor Air Flow Volume | m3/h | 7000 |
| Outdoor Air Flow Volume | CFM | 4119.5 |
| Outdoor Sound Pressure Level (H) | dB(A) | 60 |
| Outdoor Sound Power Level (Test) | dB(A) | 73 |
| Dehumidifying Volume | L/h | 4.5 |
| Rated Voltage | V | 220-240 |
| Rated Frequency | Hz | 50/60 |
| Phases | - | 1 |
| Min/Max. Voltage | V | 198/264 |
| Cross-sectional Area of Power Cable Conductor | mm2 | 6 |
| Cross-sectional Area of Power Cable Conductor | sq in | 0.0093 |
| Recommended Power Cable(Core) | N | 3 |
| Indoor Fuse Current | A | 10 |
| Outdoor Fuse Current | A | — |
| Circuit Breaker | A | 40 |
| Application Area | m2 | 95-140 |
| Compressor Type | - | Inverter Rotary |
| Compressor Quantity | - | 1 |
| Compressor Capacity | W | 15320 |
| Compressor Power Input | W | 3830 |
| Compressor Rated Load Amp (RLA) | A | 7.2 |
| Indoor Fan Type | - | Centrifugal |
| Indoor Fan Quantity | - | 2 |
| Outdoor Fan Type | - | Axial-flow |
| Outdoor Fan Quantity | - | 2 |
| Fan Motor Drive Type | - | Direct |
| Outdoor Fan Motor Speed | rpm | 840 |
| Condenser Max. Allowable Pressure | MPa | 10 |
| Permissible Excessive Operating Pressure for the Discharge Side | MPa | 4.6 |
| Permissible Excessive Operating Pressure for the Suction Side | MPa | 2.5 |
| Maximum Allowable Pressure | MPa | 4.6 |
| High Presser Overload Protector | MPa | Protection:4.6 Recovery:3.8 |
| Low Presser Overload Protector | MPa | Protection:0.05 Recovery:0.15 |
| Cooling Operation Ambient Temperature Range | ℃ | -15~52 |
| Cooling Operation Ambient Temperature Range | ℉ | 5~125.6 |
| Heating Operation Ambient Temperature Range | ℃ | -15~24 |
| Heating Operation Ambient Temperature Range | ℉ | 5~75.2 |
| Defrosting Method | — | Auto defrost |
| Isolation | - | I |
| Outdoor Moisture Protection | — | IPX4 |
| Overload Protector | - | High Presser Protector, Discharge High Temperature Protection |
| Climate Type | - | T1 |
| Refrigerant | - | R32 |
| Refrigerant Charge | kg | 3.3 |
| Throttling Method | - | Electronic expansion valve |
| Connection Pipe Length | m | 7.5 |
| Test Connection Pipe Length | m | 7.5 |
| Not Additional Gas Connection Pipe Length | m | 15 |
| Connection Pipe Gas Additional Charge | g/m | 35 |
| Connection Pipe Outer Diameter of Liquid Pipe | mm | φ9.52 |
| Connection Pipe Outer Diameter of Liquid Pipe | inch | 3/8″ |
| Connection Pipe Outer Diameter of Gas Pipe | mm | φ16 |
| Connection Pipe Outer Diameter of Gas Pipe | inch | 5/8″ |
| Connection Pipe Max. Height Distance | m | 30 |
| Connection Pipe Max. Length Distance | m | 75 |
| Suppliy Air Outlet (W x H) | mm | 850 x 190 |
| Return Air Inlet (W x H) | mm | 1170 x 326 |
| Indoor Dimension of Outline(W x D x H) | mm | 1350 x 720 x 360 |
| Indoor Dimension of Carton Box(L x W x H) | mm | 1565 x 861 x 433 |
| Indoor Dimension of Package(L x W x H) | mm | 1568 x 864 x 448 |
| Indoor Net Weight (Net/Gross) | kg | 60 / 70 |
| Outdoor Dimension of Outline(W x D x H) | mm | 900 x 340 x 1260 |
| Outdoor Dimension of Carton Box(L x W x H) | mm | 1025 x 435 x 1285 |
| Outdoor Dimension of Package(L x W x H) | mm | 1033 x 443 x 1405 |
| Outdoor Net Weight (Net/Gross) | kg | 97 / 106 |
| Indoor Unit Loading Quantity ( 20’ Container ) | unit | 35 |
| Indoor Unit Loading Quantity ( 40’ Container ) | unit | 75 |
| Indoor Unit Loading Quantity ( 40’ High Cube Container ) | unit | 75 |
| Indoor Unit Stacked Layers | - | 5 |
| Outdoor Unit Loading Quantity ( 20’ Container ) | unit | 27 |
| Outdoor Unit Loading Quantity ( 40’ Container ) | unit | 57 |
| Outdoor Unit Loading Quantity ( 40’ High Cube Container ) | unit | 57 |
| Outdoor Unit Stacked Layers | - | 1 |
| Loading Quantity ( 20’ Container ) | unit | 20 |
| Loading Quantity ( 40’ Container ) | unit | 42 |
| Loading Quantity ( 40’ High Cube Container ) | unit | 42 |