| Cooling Capacity | kW | 10 |
| Cooling Capacity Range | kW | 3.00-11.70 |
| Heating Capacity | kW | 12 |
| Heating Capacity Range | kW | 3.60-13.50 |
| EER | W/W | 3.7037 |
| COP | W/W | 4.0000 |
| AEER | — | 3.6853 |
| ACOP | — | 3.9821 |
| Cooling Star Rating (Hot/Avg/Cold) | - | 4 / 3.5 / 4 |
| Cooling Energy Consumption (Hot/Avg/Cold) | kWh | 2346 / 768 / 501 |
| Heating Star Rating (Hot/Avg/Cold) | - | 3 / 2.5 / 2 |
| Heating Energy Consumption (Hot/Avg/Cold) | kWh | 225 / 1581 / 4410 |
| Cooling Power Input | kW | 2.7 |
| Cooling Power Input Range | kW | 0.50-4.20 |
| Cooling Rated Power Input | kW | 4.2 |
| Cooling Current Input | A | 12.3 |
| Cooling Current Input Range | A | 2.30-20.00 |
| Cooling Rated Current | A | 20 |
| Heating Power Input | kW | 3 |
| Heating Power Input Range | kW | 0.60-4.20 |
| Heating Rated Power Input | kW | 4.2 |
| Heating Current Input | A | 13.7 |
| Heating Current Input Range | A | 2.70-20.00 |
| Heating Rated Current | A | 20 |
| Standby power consumption | W | 4 |
| Indoor Fan Motor Speed | rpm | 1320/1260/1200/1150 |
| Indoor Air Flow Volume | m3/h | 2100/1900/1700/1400 |
| Indoor Air Flow Volume | l/s | 583/528/472/389 |
| Indoor Air Flow Volume | CFM | 1235/1117/1000/824 |
| External Static Pressure | Pa | 37 |
| External Static Pressure Range | Pa | 0-160 |
| Indoor Sound Pressure Level (H) | dB(A) | 42 |
| Indoor Sound Pressure Level (M) | dB(A) | 41 |
| Indoor Sound Pressure Level (L) | dB(A) | 40 |
| Indoor Sound Power Level (Test) | dB(A) | 61 |
| Outdoor Air Flow Volume | m3/h | 4900 |
| Outdoor Air Flow Volume | CFM | 2883.65 |
| Outdoor Sound Pressure Level (H) | dB(A) | 58 |
| Outdoor Sound Power Level (Test) | dB(A) | 72 |
| Dehumidifying Volume | L/h | 3 |
| Rated Voltage | V | 220-240 |
| Rated Frequency | Hz | 50/60 |
| Phases | - | 1 |
| Min/Max. Voltage | V | 198/264 |
| Cross-sectional Area of Power Cable Conductor | mm2 | 4 |
| Cross-sectional Area of Power Cable Conductor | sq in | 0.0062 |
| Recommended Power Cable(Core) | N | 3 |
| Indoor Fuse Current | A | 3.15 |
| Outdoor Fuse Current | A | — |
| Circuit Breaker | A | 32 |
| Application Area | m2 | 46-70 |
| Compressor Type | - | Inverter Rotary |
| Compressor Quantity | - | 1 |
| Compressor Capacity | W | 9529 |
| Compressor Power Input | W | 3200 |
| Compressor Rated Load Amp (RLA) | A | 4.9 |
| Indoor Fan Type | - | Centrifugal |
| Indoor Fan Quantity | - | 3 |
| Outdoor Fan Type | - | Axial-flow |
| Outdoor Fan Quantity | - | 1 |
| Fan Motor Drive Type | - | Direct |
| Outdoor Fan Motor Speed | rpm | 780 |
| Condenser Max. Allowable Pressure | MPa | 10 |
| Permissible Excessive Operating Pressure for the Discharge Side | MPa | 4.6 |
| Permissible Excessive Operating Pressure for the Suction Side | MPa | 2.5 |
| Maximum Allowable Pressure | MPa | 4.6 |
| High Presser Overload Protector | MPa | Protection:4.6 Recovery:3.8 |
| Low Presser Overload Protector | MPa | Protection:0.05 Recovery:0.15 |
| Cooling Operation Ambient Temperature Range | ℃ | –15~52 |
| Cooling Operation Ambient Temperature Range | ℉ | 5~125.6 |
| Heating Operation Ambient Temperature Range | ℃ | –15~24 |
| Heating Operation Ambient Temperature Range | ℉ | 5~75.2 |
| Defrosting Method | — | Auto defrost |
| Isolation | - | I |
| Outdoor Moisture Protection | — | IPX4 |
| Overload Protector | - | High Presser Protector Low presser protector |
| Climate Type | - | T1 |
| Refrigerant | - | R32 |
| Refrigerant Charge | kg | 2.2 |
| Throttling Method | - | Electronic expansion valve |
| Connection Pipe Length | m | 5 |
| Test Connection Pipe Length | m | 5 |
| Not Additional Gas Connection Pipe Length | m | 15 |
| Connection Pipe Gas Additional Charge | g/m | 25 |
| Connection Pipe Outer Diameter of Liquid Pipe | mm | φ9.52 |
| Connection Pipe Outer Diameter of Liquid Pipe | inch | 3/8″ |
| Connection Pipe Outer Diameter of Gas Pipe | mm | φ16 |
| Connection Pipe Outer Diameter of Gas Pipe | inch | 5/8″ |
| Connection Pipe Max. Height Distance | m | 30 |
| Connection Pipe Max. Length Distance | m | 75 |
| Suppliy Air Outlet (W x H) | mm | 1153 x 215 |
| Return Air Inlet (W x H) | mm | 1188 x 220 |
| Indoor Dimension of Outline(W x D x H) | mm | 1340 x 655 x 260 |
| Indoor Dimension of Carton Box(L x W x H) | mm | 1562 x 773 x 300 |
| Indoor Dimension of Package(L x W x H) | mm | 1565 x 776 x 315 |
| Indoor Net Weight (Net/Gross) | kg | 43 / 49 |
| Outdoor Dimension of Outline(W x D x H) | mm | 940 x 370 x 820 |
| Outdoor Dimension of Carton Box(L x W x H) | mm | 1090 x 494 x 850 |
| Outdoor Dimension of Package(L x W x H) | mm | 1098 x 503 x 970 |
| Outdoor Net Weight (Net/Gross) | kg | 67 / 79 |
| Indoor Unit Loading Quantity ( 20’ Container ) | unit | 70 |
| Indoor Unit Loading Quantity ( 40’ Container ) | unit | 154 |
| Indoor Unit Loading Quantity ( 40’ High Cube Container ) | unit | 176 |
| Indoor Unit Stacked Layers | - | 8 |
| Outdoor Unit Loading Quantity ( 20’ Container ) | unit | 44 |
| Outdoor Unit Loading Quantity ( 40’ Container ) | unit | 92 |
| Outdoor Unit Loading Quantity ( 40’ High Cube Container ) | unit | 92 |
| Outdoor Unit Stacked Layers | - | 2 |
| Loading Quantity ( 20’ Container ) | unit | 29 |
| Loading Quantity ( 40’ Container ) | unit | 64 |
| Loading Quantity ( 40’ High Cube Container ) | unit | 74 |
| Cooling Capacity | kW | 10 |
| Cooling Capacity Range | kW | 3.00-11.70 |
| Heating Capacity | kW | 12 |
| Heating Capacity Range | kW | 3.60-13.50 |
| EER | W/W | 3.7037 |
| COP | W/W | 4.0000 |
| AEER | — | 3.6853 |
| ACOP | — | 3.9821 |
| Cooling Star Rating (Hot/Avg/Cold) | - | 4 / 3.5 / 4 |
| Cooling Energy Consumption (Hot/Avg/Cold) | kWh | 2346 / 768 / 501 |
| Heating Star Rating (Hot/Avg/Cold) | - | 3 / 2.5 / 2 |
| Heating Energy Consumption (Hot/Avg/Cold) | kWh | 225 / 1581 / 4410 |
| Cooling Power Input | kW | 2.7 |
| Cooling Power Input Range | kW | 0.50-4.20 |
| Cooling Rated Power Input | kW | 4.2 |
| Cooling Current Input | A | 12.3 |
| Cooling Current Input Range | A | 2.30-20.00 |
| Cooling Rated Current | A | 20 |
| Heating Power Input | kW | 3 |
| Heating Power Input Range | kW | 0.60-4.20 |
| Heating Rated Power Input | kW | 4.2 |
| Heating Current Input | A | 13.7 |
| Heating Current Input Range | A | 2.70-20.00 |
| Heating Rated Current | A | 20 |
| Standby power consumption | W | 4 |
| Indoor Fan Motor Speed | rpm | 1320/1260/1200/1150 |
| Indoor Air Flow Volume | m3/h | 2100/1900/1700/1400 |
| Indoor Air Flow Volume | l/s | 583/528/472/389 |
| Indoor Air Flow Volume | CFM | 1235/1117/1000/824 |
| External Static Pressure | Pa | 37 |
| External Static Pressure Range | Pa | 0-160 |
| Indoor Sound Pressure Level (H) | dB(A) | 42 |
| Indoor Sound Pressure Level (M) | dB(A) | 41 |
| Indoor Sound Pressure Level (L) | dB(A) | 40 |
| Indoor Sound Power Level (Test) | dB(A) | 61 |
| Outdoor Air Flow Volume | m3/h | 4900 |
| Outdoor Air Flow Volume | CFM | 2883.65 |
| Outdoor Sound Pressure Level (H) | dB(A) | 58 |
| Outdoor Sound Power Level (Test) | dB(A) | 72 |
| Dehumidifying Volume | L/h | 3 |
| Rated Voltage | V | 220-240 |
| Rated Frequency | Hz | 50/60 |
| Phases | - | 1 |
| Min/Max. Voltage | V | 198/264 |
| Cross-sectional Area of Power Cable Conductor | mm2 | 4 |
| Cross-sectional Area of Power Cable Conductor | sq in | 0.0062 |
| Recommended Power Cable(Core) | N | 3 |
| Indoor Fuse Current | A | 3.15 |
| Outdoor Fuse Current | A | — |
| Circuit Breaker | A | 32 |
| Application Area | m2 | 46-70 |
| Compressor Type | - | Inverter Rotary |
| Compressor Quantity | - | 1 |
| Compressor Capacity | W | 9529 |
| Compressor Power Input | W | 3200 |
| Compressor Rated Load Amp (RLA) | A | 4.9 |
| Indoor Fan Type | - | Centrifugal |
| Indoor Fan Quantity | - | 3 |
| Outdoor Fan Type | - | Axial-flow |
| Outdoor Fan Quantity | - | 1 |
| Fan Motor Drive Type | - | Direct |
| Outdoor Fan Motor Speed | rpm | 780 |
| Condenser Max. Allowable Pressure | MPa | 10 |
| Permissible Excessive Operating Pressure for the Discharge Side | MPa | 4.6 |
| Permissible Excessive Operating Pressure for the Suction Side | MPa | 2.5 |
| Maximum Allowable Pressure | MPa | 4.6 |
| High Presser Overload Protector | MPa | Protection:4.6 Recovery:3.8 |
| Low Presser Overload Protector | MPa | Protection:0.05 Recovery:0.15 |
| Cooling Operation Ambient Temperature Range | ℃ | –15~52 |
| Cooling Operation Ambient Temperature Range | ℉ | 5~125.6 |
| Heating Operation Ambient Temperature Range | ℃ | –15~24 |
| Heating Operation Ambient Temperature Range | ℉ | 5~75.2 |
| Defrosting Method | — | Auto defrost |
| Isolation | - | I |
| Outdoor Moisture Protection | — | IPX4 |
| Overload Protector | - | High Presser Protector Low presser protector |
| Climate Type | - | T1 |
| Refrigerant | - | R32 |
| Refrigerant Charge | kg | 2.2 |
| Throttling Method | - | Electronic expansion valve |
| Connection Pipe Length | m | 5 |
| Test Connection Pipe Length | m | 5 |
| Not Additional Gas Connection Pipe Length | m | 15 |
| Connection Pipe Gas Additional Charge | g/m | 25 |
| Connection Pipe Outer Diameter of Liquid Pipe | mm | φ9.52 |
| Connection Pipe Outer Diameter of Liquid Pipe | inch | 3/8″ |
| Connection Pipe Outer Diameter of Gas Pipe | mm | φ16 |
| Connection Pipe Outer Diameter of Gas Pipe | inch | 5/8″ |
| Connection Pipe Max. Height Distance | m | 30 |
| Connection Pipe Max. Length Distance | m | 75 |
| Suppliy Air Outlet (W x H) | mm | 1153 x 215 |
| Return Air Inlet (W x H) | mm | 1188 x 220 |
| Indoor Dimension of Outline(W x D x H) | mm | 1340 x 655 x 260 |
| Indoor Dimension of Carton Box(L x W x H) | mm | 1562 x 773 x 300 |
| Indoor Dimension of Package(L x W x H) | mm | 1565 x 776 x 315 |
| Indoor Net Weight (Net/Gross) | kg | 43 / 49 |
| Outdoor Dimension of Outline(W x D x H) | mm | 940 x 370 x 820 |
| Outdoor Dimension of Carton Box(L x W x H) | mm | 1090 x 494 x 850 |
| Outdoor Dimension of Package(L x W x H) | mm | 1098 x 503 x 970 |
| Outdoor Net Weight (Net/Gross) | kg | 67 / 79 |
| Indoor Unit Loading Quantity ( 20’ Container ) | unit | 70 |
| Indoor Unit Loading Quantity ( 40’ Container ) | unit | 154 |
| Indoor Unit Loading Quantity ( 40’ High Cube Container ) | unit | 176 |
| Indoor Unit Stacked Layers | - | 8 |
| Outdoor Unit Loading Quantity ( 20’ Container ) | unit | 44 |
| Outdoor Unit Loading Quantity ( 40’ Container ) | unit | 92 |
| Outdoor Unit Loading Quantity ( 40’ High Cube Container ) | unit | 92 |
| Outdoor Unit Stacked Layers | - | 2 |
| Loading Quantity ( 20’ Container ) | unit | 29 |
| Loading Quantity ( 40’ Container ) | unit | 64 |
| Loading Quantity ( 40’ High Cube Container ) | unit | 74 |
The GOLD Fin Protection on TECO air conditioners is designed to enhance durability by protecting the outdoor coils from corrosion. This added layer of protection helps maintain the unit’s efficiency, ensuring it continues to perform optimally even in harsh environments. It also works in tandem with the Self Clean function, keeping the evaporator coils cleaner for longer, which improves overall air quality and system performance.
With Built-In Wi-Fi, you can easily control your TECO air conditioner from anywhere using your smartphone or tablet. Whether you’re at home or out and about, the intuitive mobile app lets you adjust the temperature, change settings, and even schedule operations remotely. It’s also compatible with popular smart home systems like Google Home and Amazon Alexa, so you can manage your indoor climate with simple voice commands.
TECO air conditioners meet Australia’s Minimum Energy Performance Standards (MEPS), ensuring they deliver excellent energy efficiency and performance. These standards, regulated under the Greenhouse and Energy Minimum Standards Act, guarantee that TECO air conditioners operate effectively across Australia’s varied climate zones, helping you save on energy bills while keeping your home comfortable year-round.