8.2kW R32 Multi Split System
8.2kW R32 Multi Split System
Model No.
TSOM82HVAG4
  • 7 Years Warranty (Domestic application)
  • 2 Years Warranty (Commercial application)
  • Cooling Capacity: 8.2kW (2.30 ~ 11.00kW)
  • Heating Capacity: 8.8kW (2.80 ~ 10.25kW)
  • Blackfin Coating on Outdoor Unit Condenser Coil
  • DRED Enabled
  • Wide Operating Ambient Temperature Range
  • Wide Voltage Range Operation
  • Auto Restart Function
  • Outdoor Anti-Corrosion Housing (Zinc-Coated Steel Chassis)
  • Triple-Coated PCB
  • Self-Diagnosis Capability
The TSOM82HVAG4 (8.2kW) Multi-Split System is a robust and adaptable climate solution, capable of supporting 2 to 4 indoor units for customised zone control across larger homes or light commercial spaces. Built for reliable performance, it operates efficiently within a wide voltage range (160V–276V) and maintains comfort even in extreme outdoor temperatures. With built-in WiFi, optional wired controller support, and DRED compliance, it’s ideal for smart, energy-aware installations. Advanced comfort features include Dehumidify mode, Turbo fan function, and the I Feel sensor for precision climate management. The Pre-Heat function prevents cold air drafts by delaying the fan start up until the Evaporator Coil heats up in Winter , while the Ion Generator improves indoor air purity. The unit’s Black Fin-coated condenser coil, triple-coated PCB, and built-in Auto-Restart and Self-Diagnosis functions provide durability and peace of mind in diverse Australian environments.
  • 7 Years Warranty (Domestic application)
  • 2 Years Warranty (Commercial application)
  • Cooling Capacity: 8.2kW (2.30 ~ 11.00kW)
  • Heating Capacity: 8.8kW (2.80 ~ 10.25kW)
  • Black Fin Coating – Condensing Coil
    The outdoor coil features a Black Fin hydrophilic anti-corrosion coating, providing superior protection against salt spray, rain, and other harsh environmental elements. This coating extends the life of the unit and ensures efficient heat exchange capabilities, especially in coastal areas.
  • DRED Enabled
    DRED (Demand Response Enabled Device) capability allows the outdoor unit to respond to energy supplier load-shedding signals during peak demand periods. This function supports energy efficiency schemes and energy suppliers manage power distribution in peak periods.
  • Wide Operating Temperature Range
    The system is engineered to operate in a wide range of outdoor temperatures, from -15°C to 52°C in cooling and -15°C to 24°C in heating. This ensures dependable year-round performance, even in extreme Australian conditions.
  • Wide Voltage Operating Range (160V–276V)
    With a wide voltage tolerance, the outdoor unit operates safely and consistently during fluctuations in power supply. This feature is especially valuable in rural or regional areas where voltage instability is common.
  • Auto Restart Function
    In the event of a power outage, the system automatically restarts with the previous settings once power is restored. This ensures continued comfort and prevents the need for manual resets, which is particularly useful in unattended holiday homes or offices.
  • Outdoor Anti-Corrosion Housing (Zinc-Coated Steel Chassis)
    The outdoor unit housing is constructed from zinc-coated steel and painted to resist rust and corrosion. This robust build is ideal for Australian environments and helps maintain the system’s aesthetic and mechanical integrity over time.
  • Triple-Coated PCB
    The outdoor PCB is treated with three layers of protective coating, to improve moisture resistance and durability. This feature enhances reliability in humid and coastal climates, reducing the risk of electrical faults.
  • Self-Diagnosis Capability
    The system continuously monitors its own operation and displays error codes if a fault is detected. This simplifies troubleshooting for installers and service technicians, speeding up maintenance and minimising system downtime.
Model TSOM82HVAG4
EAN 9346998006947
Cooling Capacity kW 8.2
Min. Cooling Capacity W 2300
Max. Cooling Capacity W 11000
Cooling Power Input kW 1.88
Cooling Current Input A 8.341
Heating Capacity kW 8.8
Min. Heating Capacity W 2800
Max. Heating Capacity W 10250
Heating Power Input kW 2.12
Heating Current Input A 9.406
Rated Power Input kW 3.6
Rated Current A 15.972
Starting Current A 5
Standby power consumption W 10
EER W/W 4.362
COP W/W 4.151
SEER TCSPF=5.2
HSPF 4.5
SCOP(Average) /
AEER 4.2847
ACOP 4.0858
Cooling Star Rating (Cold/Mixed/Hot&Humid) 3.5 / 3.5 / 4
Cooling Energy Consumption (Cold/Mixed/Hot&Humid) kWh 408 / 1262 / 1814
Heating Star Rating (Cold/Mixed/Hot&Humid) 2 / 3 / 3.5
Heating Energy Consumption (Cold/Mixed/Hot&Humid) kWh 3032 / 1087 / 333
Air Flow Volume m3/h 3800
Sound Pressure Level dB(A) 58
Sound Power Level (EN 12102-1:2017) dB(A) 68.8
Rated Voltage V 220-240
Rated Frequency Hz 50
Phases 1
Min/Max. Voltage V 198/264
Compressor Type1 Twin Rotary
Fan Type Axial-flow
Fan Quantity 1
Fan Motor Type DC motor
Condenser Material Aluminum Fin-copper Tube
Condenser Fin Type corrugated
Condenser Fin Colour Black
Cooling Operation Ambient Temperature Range -15~52
Heating Operation Ambient Temperature Range -22~24
Maximum drive IDU NO. unit 4
Defrosting Method Automatic Defrosting
Isolation I
Moisture Protection IPX4
Climate Type T1
Refrigerant R32
Refrigerant Charge kg 1.8
Throttling Method Electron expansion valve
Climate Zone Temperate Zone
Connection Pipe Connection Method Flare Connection
Liguid Pipe 4 x Ø6 (1/4″)
Gas Pipe 4 x Ø9.52 (3/8″)
Operating Pressure (Discharge/Suction) MPa 4.3/2.5
Maximum Allowable Pressure MPa 4.3
Not Additional Gas Connection Pipe Length m 40
Connection Pipe Gas Additional Charge g/m 20
Connection Pipe Max. Height Distance (indoor and indoor) m 15
Connection Pipe Max. Height Distance (indoor and outdoor and indoor up) m 15
Connection Pipe Max. Height Distance (indoor and outdoor and outdoor up) m 15
Max. equivalent connection pipe length (outdoor to last indoor) m 30
Connection Pipe Max. Length Distance (total lenght) m 70
Low Ambient Cooling Function YES
Low Voltage Startup YES
Demand Response Capability (AS/NZS 4755.3.1:2014) YES
Dimension of Outline(W) mm 964
Dimension of Outline(D) mm 402
Dimension of Outline(H) mm 660
Dimension of Carton Box(L) mm 1029
Dimension of Carton Box(W) mm 453
Dimension of Carton Box(H) mm 700
Dimension of Package(L) mm 1040
Dimension of Package(W) mm 463
Dimension of Package(H) mm 805
Net Weight kg 51
Gross Weight kg 63.5
Outdoor Unit Loading Quantity ( 20’ Container ) unit 48
Outdoor Unit Loading Quantity ( 40’ Container ) unit 100
Outdoor Unit Loading Quantity ( 40’ High Cube Container ) unit 150
Outdoor Unit Stacked Layers 3

Features

  • 7 Years Warranty (Domestic application)
  • 2 Years Warranty (Commercial application)
  • Cooling Capacity: 8.2kW (2.30 ~ 11.00kW)
  • Heating Capacity: 8.8kW (2.80 ~ 10.25kW)
  • Black Fin Coating – Condensing Coil
    The outdoor coil features a Black Fin hydrophilic anti-corrosion coating, providing superior protection against salt spray, rain, and other harsh environmental elements. This coating extends the life of the unit and ensures efficient heat exchange capabilities, especially in coastal areas.
  • DRED Enabled
    DRED (Demand Response Enabled Device) capability allows the outdoor unit to respond to energy supplier load-shedding signals during peak demand periods. This function supports energy efficiency schemes and energy suppliers manage power distribution in peak periods.
  • Wide Operating Temperature Range
    The system is engineered to operate in a wide range of outdoor temperatures, from -15°C to 52°C in cooling and -15°C to 24°C in heating. This ensures dependable year-round performance, even in extreme Australian conditions.
  • Wide Voltage Operating Range (160V–276V)
    With a wide voltage tolerance, the outdoor unit operates safely and consistently during fluctuations in power supply. This feature is especially valuable in rural or regional areas where voltage instability is common.
  • Auto Restart Function
    In the event of a power outage, the system automatically restarts with the previous settings once power is restored. This ensures continued comfort and prevents the need for manual resets, which is particularly useful in unattended holiday homes or offices.
  • Outdoor Anti-Corrosion Housing (Zinc-Coated Steel Chassis)
    The outdoor unit housing is constructed from zinc-coated steel and painted to resist rust and corrosion. This robust build is ideal for Australian environments and helps maintain the system’s aesthetic and mechanical integrity over time.
  • Triple-Coated PCB
    The outdoor PCB is treated with three layers of protective coating, to improve moisture resistance and durability. This feature enhances reliability in humid and coastal climates, reducing the risk of electrical faults.
  • Self-Diagnosis Capability
    The system continuously monitors its own operation and displays error codes if a fault is detected. This simplifies troubleshooting for installers and service technicians, speeding up maintenance and minimising system downtime.

Specifications

Model TSOM82HVAG4
EAN 9346998006947
Cooling Capacity kW 8.2
Min. Cooling Capacity W 2300
Max. Cooling Capacity W 11000
Cooling Power Input kW 1.88
Cooling Current Input A 8.341
Heating Capacity kW 8.8
Min. Heating Capacity W 2800
Max. Heating Capacity W 10250
Heating Power Input kW 2.12
Heating Current Input A 9.406
Rated Power Input kW 3.6
Rated Current A 15.972
Starting Current A 5
Standby power consumption W 10
EER W/W 4.362
COP W/W 4.151
SEER TCSPF=5.2
HSPF 4.5
SCOP(Average) /
AEER 4.2847
ACOP 4.0858
Cooling Star Rating (Cold/Mixed/Hot&Humid) 3.5 / 3.5 / 4
Cooling Energy Consumption (Cold/Mixed/Hot&Humid) kWh 408 / 1262 / 1814
Heating Star Rating (Cold/Mixed/Hot&Humid) 2 / 3 / 3.5
Heating Energy Consumption (Cold/Mixed/Hot&Humid) kWh 3032 / 1087 / 333
Air Flow Volume m3/h 3800
Sound Pressure Level dB(A) 58
Sound Power Level (EN 12102-1:2017) dB(A) 68.8
Rated Voltage V 220-240
Rated Frequency Hz 50
Phases 1
Min/Max. Voltage V 198/264
Compressor Type1 Twin Rotary
Fan Type Axial-flow
Fan Quantity 1
Fan Motor Type DC motor
Condenser Material Aluminum Fin-copper Tube
Condenser Fin Type corrugated
Condenser Fin Colour Black
Cooling Operation Ambient Temperature Range -15~52
Heating Operation Ambient Temperature Range -22~24
Maximum drive IDU NO. unit 4
Defrosting Method Automatic Defrosting
Isolation I
Moisture Protection IPX4
Climate Type T1
Refrigerant R32
Refrigerant Charge kg 1.8
Throttling Method Electron expansion valve
Climate Zone Temperate Zone
Connection Pipe Connection Method Flare Connection
Liguid Pipe 4 x Ø6 (1/4″)
Gas Pipe 4 x Ø9.52 (3/8″)
Operating Pressure (Discharge/Suction) MPa 4.3/2.5
Maximum Allowable Pressure MPa 4.3
Not Additional Gas Connection Pipe Length m 40
Connection Pipe Gas Additional Charge g/m 20
Connection Pipe Max. Height Distance (indoor and indoor) m 15
Connection Pipe Max. Height Distance (indoor and outdoor and indoor up) m 15
Connection Pipe Max. Height Distance (indoor and outdoor and outdoor up) m 15
Max. equivalent connection pipe length (outdoor to last indoor) m 30
Connection Pipe Max. Length Distance (total lenght) m 70
Low Ambient Cooling Function YES
Low Voltage Startup YES
Demand Response Capability (AS/NZS 4755.3.1:2014) YES
Dimension of Outline(W) mm 964
Dimension of Outline(D) mm 402
Dimension of Outline(H) mm 660
Dimension of Carton Box(L) mm 1029
Dimension of Carton Box(W) mm 453
Dimension of Carton Box(H) mm 700
Dimension of Package(L) mm 1040
Dimension of Package(W) mm 463
Dimension of Package(H) mm 805
Net Weight kg 51
Gross Weight kg 63.5
Outdoor Unit Loading Quantity ( 20’ Container ) unit 48
Outdoor Unit Loading Quantity ( 40’ Container ) unit 100
Outdoor Unit Loading Quantity ( 40’ High Cube Container ) unit 150
Outdoor Unit Stacked Layers 3
  • Larger Residential Homes – Ideal for multi-room climate control in bigger households, offering enhanced capacity for bedrooms, living areas, and studies.
  • Medium-sized apartments & Commercial Spaces – Suitable for apartments and office environments needing independent temperature zones for improved comfort.
  • Retail & Hospitality Venues – Ensures consistent cooling and heating across multiple areas such as boutique stores, cafés, and reception areas.
  • Healthcare & Professional Offices – Provides reliable, quiet, and efficient climate control for consultation rooms, patient areas, and shared workspaces.

Ideal Use Cases

  • Larger Residential Homes – Ideal for multi-room climate control in bigger households, offering enhanced capacity for bedrooms, living areas, and studies.
  • Medium-sized apartments & Commercial Spaces – Suitable for apartments and office environments needing independent temperature zones for improved comfort.
  • Retail & Hospitality Venues – Ensures consistent cooling and heating across multiple areas such as boutique stores, cafés, and reception areas.
  • Healthcare & Professional Offices – Provides reliable, quiet, and efficient climate control for consultation rooms, patient areas, and shared workspaces.